Custom Report Templates

Scroll Prev Top Next More

Custom report templates can be added in subdirectory “templates/module-id”. Reports based on these templates can be generated by selecting the report template under Report->Report templates.

The report templates are word files with DOCVARIABLE fields. These fields are filled on generation of the report.

Possible fields are:

DOCVARIABLE VAR name [unit]: the variable with the name ‘name’ is printed. Optionally a unit can be provided in brackets, for example [mm]. Additionally, a format could be added like %6.3g or %6.3f, where ‘f’ always generates a fixed point output and ‘g’ generates an exponential output for large numbers.

DOCVARIABLE VARU name [unit]: the variable with the name ‘name’ plus the unit are printed. Optionally a unit can be provided in brackets, for example [mm].

DOCVARIABLE TABLE tablename: A table is inserted.

DOCVARIABLE GRAPHIC graphicName width=130 height=70: A graphic is inserted. Optionally height and width can be given in millimeters.

Regarding details for variable names, table names and graphic names please ask support@mesys.ch for additional documentation.